Batch Weigher Training Manual Calibration How to Enter Calibration Mode 1. Turn off the Batch Weigher isolator. 2. Turn on the Batch Weigher isolator. After power up of the Batch Weigher, the display shows for approx. 3 sec the power up message: After this...
More
Batch Weigher Training Manual Calibration How to Enter Calibration Mode 1. Turn off the Batch Weigher isolator. 2. Turn on the Batch Weigher isolator. After power up of the Batch Weigher, the display shows for approx. 3 sec the power up message: After this press “INFO” key, you can select calibration mode. It will be at number 2. You can see all group as follows. W1 Scale Select Group 19 1. Select calibration group: 2. Scale Parameters 3. Calibration 4. Linearization 5. Zero Adjust 6. Adaptation 7. High Resolution (tenfold resolution) 8. Reset Parameters 9. Calculate Span: Calibration without test weights 10. W&M Info After entering the calibration mode we will perform zero calibration (with no load on batch weighers) and maximum load calibration (1000KG chief certified dead weights). You have to enter the values as follows.