BUS_Error Alarms on 40G card due to different hardware types Publication Date: 2012-07-25 Views: 1 Downloads: 0 References: 0 Issue Description The ring is compromised of 8 OSN 6800 sites and different type of traffic are configured NE version is 5.51.05.35...
More
BUS_Error Alarms on 40G card due to different hardware types Publication Date: 2012-07-25 Views: 1 Downloads: 0 References: 0 Issue Description The ring is compromised of 8 OSN 6800 sites and different type of traffic are configured NE version is 5.51.05.35 Alarm Information BUS_ERR alarm on Huawei NS3 card Handling Process First of all check the service configuration and all services were configured correctly and as per requirement both client and network side services were same.We need to take care of service type either we are using standard or speedup services Standard are using for Traditional 10 G services Speedup are using for Ethernet services higher than 10 G Check hardware ,hardware is also working giving the same alarms on other node also when we inserted the same card,when we check the module type of both cards on both NEs we find the on one site there was TN52NS3T03 and on other site there was TN52NS3T01. TO3 is used for short haul and T01 is used for Long Haul communicati
Less